Charger SELECT
1 kW
Banner SELECT chargers
Maximum energy efficiency
Banner chargers are highly intelligent. In addition to their appealing design, these charging systems are especially impressive because of their technical innovations. The successful Active Inverter technology with the revolutionary Ri charging process adapts to battery requirements and delivers only the power that is actually needed into the battery.
HOW THE NEW RI CHARGING PROCESS WORKS
- Determination of battery condition from the internal resistance
- Characteristic curve adaptation to battery age, temperature and state of charge
- Optimum power supply in every charging phase
- Demand-based characteristic curve for each cycle
Adapting the current to the battery means that charging losses can be avoided at the beginning of the charging cycle as well as during the recharging phase. The battery only gets the current it really needs. That way, the new Ri charging process guarantees the coolest and gentlest charging. Which in turn ensures maximum battery life.
Dimensions W/H/D: | 247 x 162 x 88 mm |
Weight incl. charging and mains cables |
2 kg |
Protection class: | IP40 |
Mains cable: | 2 m |
Charging cable: | 2,5 m |
Mains voltage: | 1x 230V AC (+/-10%) |
Art. no.: |
Max. Charging voltage (V) |
Charging current (A) |
Wet batteries (PzS) |
VRLA battery |
Device type |
Mains fuse |
|||||
Capacity (Ah) |
Capacity (Ah) | ||||||||||
6h | 8h | 10h | 12h | 10h | 12h | 14h | |||||
0433105100 | 24 | 15 | 80 | 125 | 170 | 210 | 80 | 105 | 120 | HF + 2015 | 3A |
0433105200 | 24 | 20 | 110 | 165 | 225 | 280 | 120 | 140 | 160 | HF + 2020 | 4A |
0433105300 | 24 | 32 | 180 | 260 | 360 | 450 | 190 | 205 | 220 | HF + 2032 | 8A |
0433105400 | 24 | 40 | 200 | 290 | 395 | 490 | 220 | 250 | 280 | HF + 2040 | 8A |
The allocation table refers to a battery that is 70% discharged.